Abstract

Research Article

Social Implementation and Measurement Accuracy Verification of Non-contact Biological Monitors

Shinji Kondo and Wakita Yoshinori*

Published: 25 March, 2024 | Volume 8 - Issue 1 | Pages: 011-021

In this research, for the purpose of social implementation, we conducted a near-miss demonstration experiment using a car driving in the city and a drive-simulator. Next, we conducted a demonstration experiment to evaluate the reliability of biometric information measured on patients in a medical facility's recuperation ward and residents of a special nursing home. NBC-1100 emits radar waves from a distance of up to 3 meters from an object and uses the reflected waves to measure biological information such as pulse waves and breathing waves. 
The multi-element pyroelectric effect was used to measure body temperature by detecting infrared radiation emitted from distant objects. This device is unique in that it can measure biological information without being restrained while wearing clothes. 
In the demonstration test, simultaneous measurements were conducted on nine healthy men aged 45 to 65 using a pharmaceutically approved product (μBP-mp) and a prototype non-contact biological monitor (NBC-1100 manufactured by K&S Co., Ltd.). 
The demonstration experiments at medical institutions and nursing care facilities were conducted with the consent of residents and their families and were conducted on 30 men and women between the ages of 70 and 94 who were undergoing treatment or in need of care. 
The tests were conducted on residents with chronic diseases such as dilated gastrostomies, symptomatic epilepsy, hypertension, Alzheimer's disease, and progressive supranuclear palsy. The evaluation method was simultaneous measurement using a master meter (μBP-mp) and a test meter (NBC-1100).

Read Full Article HTML DOI: 10.29328/journal.cjncp.1001052 Cite this Article Read Full Article PDF

Keywords:

Radar sensor; Non-contact monitor; Deep plethysmogram; Central blood pressure; Telemedicine; Deterioration of the condition; Sudden death; Home medical treatment; Prehospital diagnosis; Home care

References

  1. Yamamoto M, Iwamoto J. Research on the differences in blood pressure measurement using an oscillometric automatic blood pressure monitor and a mercury blood pressure monitor. Journal of the Japanese Society of Nursing Technology. 2008; 7: 20.
  2. Medical Device Center (Foundation): Basic knowledge of medical devices, 2nd edition: 2008: Related to biological phenomenon measurement and monitoring systems, blood pressure monitors and blood pressure monitors
  3. Koshirai R. Aerial Laser Surveyor: 2004: Geospatial Information Authority of Japan Technical Data H. 1-No.4
  4. Sato M, Kawaguchi T. Development of a simple functional reach test using a laser rangefinder: 2021: Aomori Health, Medical and Welfare Research 3 (2): 35-40
  5. Iwasa I, Nasu K, Soeda M, Yamamoto K. Understanding the state of stray actual behavior using 3D laser sensors: Architectural Institute of Japan Technical Report. 2020; 26: 239-24.
  6. Matsumoto H, Fujima I. Measuring long distances with lasers. Measurement and Control. 1992; 31.
  7. Takahashi R, Tsutsui T, Kashiwagi Y, Funato K. Evaluation method for short-distance sprinting ability using a laser Doppler distance measurement device - Comparison of university softball players and short-distance track and field athletes - Nippon Sport Science University Bulletin of Nippon Sport Sci. Univ. 2013; 42(2): 103–110.
  8. David MP. Microwave Engineering: 2021: ISBN978-4-627-78644-8
  9. Matsumura T. Principles of Microwave Chemistry - Microwave Electric Field and Dielectric Properties of Materials. Chemistry and Education. 2006; 54.
  10. Mase J, Tobimatsu S, Hojo H, Chikagi Y. Biological measurement using microwave active sensors and its applications: Society of Instrument and Control Engineers. 2011; 50: 233-242.
  11. Mase J, Tobimatsu S, Hojo H, Chikagi Y: Development of advanced microwave living body detection system. Japanese Journal of Applied Physics. 2008; 47: 4755-4758.
  12. Honma N, Nishimori K. Research on biological activity detection method using microwaves to realize health monitoring system: Telecommunications Promotion Foundation Research Survey Report. 2013.
  13. Eong-suk K. Biological signal measurement using microwaves and millimeter waves: 2018: Institute of Electronics, Information and Communication Engineers IEICE technical report. MICT2017-55
  14. Iwata J, Tanaka Y, Sakamoto T. Study on the measurable distance of biological signals using millimeter wave radar: Electronic Information and Communication Technical Report. 2023; 123; 249- 254.
  15. Sakamoto T. Human body sensing using millimeter wave radar: Transactions of the Institute of Electronics, Information and Communication Engineers. 412-420.
  16. Arakawa T. A Review of Heartbeat Detection Systems for Automotive Applications: International Sensors. 2021; 21: 6112
  17. Arakawa T, Sakakibara N, Kondo S. Development of non-invasive steering-type blood pressure sensor for driver state detection. ICIC International. 2018. ISSN 1349-4198 pp. 1–1712-035
  18. Temperature can be measured in a short time without contact, regardless of distance! Application of thermopile.Design and production of non-contact temperature sensor for experiment: 2021: SSC Co., Ltd.
  19. Tanaka K, Yoshimura T. Is heart rate prescription recommended for aerobic exercise?. Physical Fitness Science. 2020; 69: 285-288 DOI: 10.7600/jspfsm.69.285
  20. Yamaji K. Exercise and heart rate: 2001: Lecture at the 55th Japanese Society of Physical Fitness Medicine. Physical Fitness Science. 2001; 50: 1-6.
  21. D'Souza A, Bucchi A, Johnsen AB, Jit S, Logansa RJ, Monfredi O, Yani J, Prehar S, Hart G, Cartwright E, Wislov U, Dobriznsky H, DiFrancesco D, Morris GM, Boyett MR. Cardiology. Why people who exercise regularly have low heart rates: Nature Communications. 2014.
  22. SSC (Co., Ltd.): Temperature can be measured in a short time without contact, regardless of distance! Application of thermopile, 2021: Design and production of non-contact temperature sensor for experiment.
  23. Nakamura H. Basics of infrared radiation thermometers: 2009: Japan Society of Mechanical Engineers Thermal Engineering Division Seminar.
  24. Takada M, Tsuneda T, Shimakura J, Laozi Y, Inado S, Ohara M, Kinuno H. Current status and issues of oscillometric automatic blood pressure monitors: General Health Checkup. 2015; 42.
  25. Yamamoto M, Iwamoto J. Research on the difference in blood pressure measurement using an oscillometric automatic blood pressure monitor and a mercury blood pressure monitor: Journal of the Japanese Society of Nursing Technology. 2008; 7.
  26. Okubo T, Tatsumi Y, Asayama T. Review (Circulatory disease health checkup techniques and criteria.
  27. Okubo T, Tatsumi Y, Asayama K. Review (Circulatory disease health checkup techniques and criteria ③) Blood pressure measurement method: Journal of the Japanese Society for Cardiovascular Disease Prevention. 2021; 56.
  28. Kondo S. Biological information measuring device: 2021: Patent No. 6941720
  29. Arakawa T, Sakakibara N, Kondo H. Development of an infrared non-contact continuous blood pressure monitor and attempt to detect change points based on statistical methods: Biomedical Engineering Symposium. 2019.
  30. Arakawa T, Tanaka M,Obayashi F, Kondo S. Detection of Driver’s Surprised State Based on Blood Pressure. ICIC International. 2012; 1–6.
  31. Tanakaa M,Obaytthia F,Arakawaa T,Kondo S, Kozuka K. Detection of Driver's Surprised State BaSed on Blood Pressure and Consideration about Sensitivity of Surprised. CISIP2014:
  32. Tanakaa M,Arakawa T, Obayashi F, Kondo S,Kozuka K. Detection of Driver’s Surprised State Based on Blood Pressure; ICIC International. 2012.
  33. Tanakaa M,Sakakibara N,Kondo S. Development and Evaluation of Infrared Blood Pressure Monitoring System and Proposal for Driver State Monitoring Human Machine Interface. Submitted to Sensors. 2020; 1–1.
  34. Tanakaa M,Sakakibara N,Kondo S. Development of a Portable Infrared-type Noncontact Blood Pressure Measuring Device and Evaluation of Blood Pressure Elevation during Driving. Springer Science+Business Media, LLC, part of Springer Nature 2020 M Sawan (ed.), Handbook of Biochips. 2020.
  35. Maeda Y, Sekine M, Tamura T, Mizutani K. Estimating autonomic nerve function using pulse waves Verification of variation in pulse wave propagation time. Biomedical Engineering. 2016; 54 (6) 261-266.
  36. Tanaka K, Yoshimura T. Is heart rate prescription recommended for oxygenated exercise?. Physical Fitness Science. 2020; 69: 285-288. DOI: 10.7600/jspfsm.69.285
  37. Onuda T, Kasao M, Ono T, Mitsui K, Shibata J. Measuring method of variability of ventricular repolarization time (STV-QT) - On the optimal minimum heart rate. JPN. J Electrocardiology. 2014; 34.